Energy Solutions OperationsFunction and Safety Evaluations of
Secondary Lithium-ion Batteries

ENERGY
SOLUTION

We accommodate order-made testing to meet demand for evaluating the safety of secondary batteries.

As uses expand, the demand for evaluating the functioning and safety of secondary lithium-ion batteries and solid-state batteries is also rapidly growing. Jinnai is one of the few companies that can help meet this demand.

Offering flexible testing tailored to the objective is a hallmark of Jinnai. Starting with UN 38.3 and JIS C 8715-2 compliance testing, we make use of facilities and equipment that can accommodate large volumes of batteries and devise testing methods from the customer's perspective, including testing under rigorous conditions matched to use and requirements as well as safety and benchmark testing for battery packs.
Our Tahara Lithium-ion Battery Function and Safety Testing Center has acquired ISO/IEC 17025:2017 certification.

Available Testing

スワイプで表を左右にスクロールしてご覧ください。

Test type Test item Corresponding standard Test type Test item Corresponding standard
Environmental tests High-temperature holding (temperature test) JIS C 8712, 8714, 8715-2
UL1642, 2054
IEC62133, 62660-3
UN38.3
Mechanical tests Internal short circuit (FISC) JIS C 8714, 8715-2
Penetration/crush JIS C 8712, 8714, 8715-2
UL1642, 2054
IEC62133
Propagation test JIS C 8715-2 Impact UL1642, 2054
UN38.3
Altitude (low pressure) JIS C 8712
UL1642
IEC62133
UN38.3
Drop JIS C 8712, 8714, 8715-2
Thermal abuse JIS C 8712, 8714, 8715-2
Immersion/salt spray GB38031
Electrical tests External short circuit JIS C 8712, 8714, 8715-2
UL1642, 2054
IEC62133, 62619, 62660-3
Vibration UL1642, 2054
IEC62133
UN38.3
Mechanical shock IEC62133
UN38.3
Overcharge JIS C 8712, 8714, 8715-2
UL1642、2054
IEC62133, 62619, 62660-3
Analysis Generated gas analysis (GC/MS)  
Accelerating rate calorimetry (ARC)  
Degradation analysis  
Forced discharge JIS C 8712, 8715-2
UL1642, 2054
IEC62133, 62619, 62660-3
UN38.3
Charge/discharge test Charge/discharge JIS C 8711, 8715-2
IEC62660-1
Cycle test Cycle JIS C 8711, 8715-2
IEC62660-1

About ISO/IEC 17025

The Tahara Lithium-ion Battery Function and Safety Testing Center (Tahara Test Center) acquired certification under the ISO/IEC 17025:2017 standard on December 9, 2021.

Note: ISO/IEC 17025 is an international standard prescribing general requirements relating to capabilities for conducting testing as a test laboratory, and comprises management-related requirements for the test laboratory's management system and technical requirements relating to technical capabilities.

Along with ISO/IEC 17025 certification, we conduct testing and inspection operations while maintaining a highly reliable technical capacity and quality management system that meet international standards and adhering closely to testing-facility quality manuals, making improvement the objective.

お打ち合わせ、試験内容の企画、見積書の提出、秘密保持契約締結、供試体受け渡し、試験実施、報告書・データ提出

Flow of Commissioned Operations

Preliminary Discussions, Planning of Test Content, Estimate Submission, Signing of Nondisclosure Agreement, Receipt of Test Samples, Testing、Delivery of Reports and Data

  • Preliminary Discussions
  • Planning of Test Content
  • Estimate Submission
  • Signing of Nondisclosure Agreement
  • Receipt of Test Samples
  • Testing
  • Delivery of Reports and Data

We maintain confidentiality and provide rigorous testing with emphasis on impartiality.

Inquiries

Energy Solutions Operations
Jinnai Industries Inc.

Contact Form